Medical Equipment, Horizontal Sterilizer, Professional Autoclave manufacturer / supplier in China, offering Thr-280ydc Hospital Medical Horizontal Autoclave B Class Sterilizer, Aluminum Alloy Funeral Ambulance Transport Stretcher (THR-3A2), Stainless Stretcher with Side Protection and so on.

(/ )

Supplier Homepage Product Medical Equipment Autoclave Thr-280ydc Hospital Medical Horizontal Autoclave B Class Sterilizer

Thr-280ydc Hospital Medical Horizontal Autoclave B Class Sterilizer

FOB Price: US $8,772 / Piece
Min. Order: 1 Piece
Min. Order FOB Price
1 Piece US $8,772/ Piece
Get Latest Price
Port: Shanghai, China
Production Capacity: 200 Piece/Pieces Per Month
Payment Terms: L/C, T/T, Western Union

Request a custom order and have something just for you!

Send Customized Request
Basic Info
  • Model NO.: THR-280YDC
  • Type: Pressure Steam Sterilization Equipments
  • Electric Tension: 220V
  • Ultra High Temperature Alarm: Without Ultra High Temperature Alarm
  • Material: Stainless Steel
  • Transport Package: Wooden Case
  • Origin: Jiangsu, China (Mainland)
  • Theory: Autoclave
  • Certification: CE, ISO13485
  • LCD Display: Without LCD Display
  • Sterilization Information Recording and Printing: Sterilization Information Recording and Printing
  • Trademark: THR
  • Specification: 280L(dia600*1000)mm
Product Description
             THR-280YDC hospital medical horizontal autoclave b class sterilizere b class sterilizer
 
Specification:
-Sterilizing Volume: 280L(dia600*1000)mm
-Working Pressure 0.22MPa
-Working Temperature 134°C
-Adjustable Temperature 40 °C-134 °C
-Heat Average ≤±2 °C
-Time of drying 0-60mins
-Time of sterilization 0-60mins
-Power 12KW/380V,50Hz
-Overall Size 770*1400*1780mm
-Packing Size 960*1650*2000mm
-G/N.W:340/440KG
Descriprion:
1.The steam can't go through to chamber when the door haven't close,and the pilot off inform.You can processing dry operate.
2.When the pressure inner over 0.027MPa,the door should be locked and can't be open.
3.If you not choose the sterilzing time and star the machine,buzzer sound.
4.If you mistake open the door in the course of start,the jacker value auto off and open the chamber value.
5.Lack water the pilot on,heating and sterilize pilot off,the buzzer sound and auto release steam.
6.Overload and leakage protection,when leakage or over current occur,it auto off the power.
7.Temperature controlled not work and the inner pressure over 0.165MPa,the safety value auto start open.


Various types of sterilizers for your chioce:
Technical dataTHR-150YDCTHR-200YDCTHR-280YDCTHR-400YDC
Sterilizing chamber volume150L
Φ480*850
200L
Φ515*1000mm
280L
Φ600*1000mm
400L
Φ700*1100mm
Working pressure0.22MPa
Working temperature134°C
Adjustment of temperature40°C-134°C
Time of sterilization0-99min
Time of drying0-99min
Heat average≤±2°C
Power9kw/380V 50Hz9kw/380V 50Hz12kw/380V 50Hz18kw/380V 50Hz
Dimension1400*600*13001400*670*16501400*770*17801430*880*1830
Transport dimension1550*750*18501560*820*18501680*920*21001600*1050*2100
G.W/N.W320/240kg350/260kg465/365kg530/420kg


 