Horizontal Cylindrical Pressure Steam Sterilizer (THR-500YDA)

Theory: Autoclave
Type: Pressure Steam Sterilization Equipments
Certification: CE
Electric Tension: 220V
LCD Display: Without LCD Display
Ultra High Temperature Alarm: Ultra High Temperature Alarm
Customization:

Contact Supplier

Diamond Member Since 2009

Suppliers with verified business licenses

Manufacturer/Factory, Trading Company

Basic Info.

Model NO.
THR-500YDA
Sterilization Information Recording and Printing
Without Sterilization Information Recording and Printing
Model
Autoclave
Transport Package
Standard Export Wooden Case
Specification
CE, ISO
Trademark
THR
Origin
Jiangsu, China
Production Capacity
200 Units/ Month

Product Description

Horizontal Cylindrical Pressure Steam Sterilizer
(THR-500YDA)
Horizontal Cylindrical Pressure Steam Sterilizer (THR-500YDA)

 
 
Model THR-150YDA THR-200YDA THR-280YDA THR-400YDA THR-500YDA
Sterilizing Chamber volume 150L
φ440*1000mm
200L
φ515*1000mm
280L
φ600*1000mm
400L
φ700×1100mm
500L
φ700×1300mm
Working pressure 0.22MPa
Working temperature 134ºC
Adjustment of temperature 105ºC - 134ºC
Time of sterilization 0-60 min
Time of drying 0-60 min
Heat average ≤±1ºC
Power 9KW/380V 50Hz 12KW/380V 50Hz 18KW/380V 50Hz
Dimension(mm) 1400*600*1300 1400*670*1650 1400*770*1780 1430*880*1830 1800*900*1820
Transport dimension(mm) 1550*750*1850 1560*820*1850 1680*920*2100 1800*1050*2100 1850*1050*2100
G.W/N.W(kg) 320/240 350/260 465/365 530/420 580/470

Characteristics
1. The steam can't go through to chamber when the door haven't close, and the pilot off inform. You can processing dry operate.
2. When the pressure inner over 0.027MPa, the door should be locked and can't be open.
3. If you not choose the sterilzing time and star the machine, buzzer sound.
4. If you mistake open the door in the course of start, the jacker value auto off and open the chamber value.
5. Lack water the pilot on, heating and sterilize pilot off, the buzzer sound and auto release steam.
6. Overload and leakage protection, when leakage or over current occur, it auto off the power.
7. Temperature controlled not work and the inner pressure over 0.165MPa, the safety value auto start open.
 

Send your message to this supplier

*From:
*To:
avatar Mr. Aamon
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

Product Groups

Contact Supplier

Diamond Member Since 2009

Suppliers with verified business licenses

Manufacturer/Factory, Trading Company
Registered Capital
2000000 RMB
Plant Area
>2000 square meters