• Medical Portable Automatic External Defibrillator (THR-MD-800C)
  • Medical Portable Automatic External Defibrillator (THR-MD-800C)
  • Medical Portable Automatic External Defibrillator (THR-MD-800C)
  • Medical Portable Automatic External Defibrillator (THR-MD-800C)
  • Medical Portable Automatic External Defibrillator (THR-MD-800C)

Medical Portable Automatic External Defibrillator (THR-MD-800C)

Function: Improve Blood Circulation
Certification: CE, ISO13485
LCD Display: With LCD Display
Group: Adult
Defibrillator Type: Manual, Synchronized, Asynchronized
out Put Waveform: Biphasic Technology
Customization:

Contact Supplier

Diamond Member Since 2009

Suppliers with verified business licenses

Manufacturer/Factory, Trading Company

Basic Info.

Model NO.
THR-MD-800C
AC Power Supply
110V, 60 Hz /220V,50 Hz
Charging Time
Maximum 8 Seconds to 360 Joules
Display
7′′ Diagonal High Resolution True-Color Graphic Le
Standard Parameter
ECG/ Resp/NIBP/ Tep/SpO2/Pr/Defibrillator
Optional Parameter
Recorder
Warranty
18month
OEM
Available
Transport Package
Standard Export Packing
Specification
CE and ISO
Trademark
THR
Origin
China
Production Capacity
100 Pieces Per Month

Product Description


External Defibrillator(THR-MD-800C) Medical Portable Automatic External Defibrillator (THR-MD-800C)
 
Physical characteristics:

Main unit: Portable
Dimensions: L320xW205xH410
Weight: 9.8kg

Technical specifications:

DEFIBRILLATOR.
(1) Defibrillator type Manual, Synchronized, Asynchronized,
(2) Out put waveform Biphasic technology
(3) Energy accuracy +1%
(4) Energy selection 0, 3, 5, 7, 10, 20, 30, 50, 100, 200, 300, 360 joule(normal at a resistance of 50)
(5) Charging time Maximum 8 seconds to 360 Joules
(6) Standard Adult/Pediatric Paddles Reusable extermal adult paddles(pediatric paddles integrated)

Power requirements.
(a) AC Power supply 110V, 60 Hz /220V, 50 Hz
(b) Vehicle Voltage DC 12V

Internal Battery Backup
(1) Battery type Rechargeable lithium battery
(2) Charging time Time-Minimum of 4 hours for full charging
(3) Battery charging During AC Power Supply operation of the device.
(4) Charging /Low Battery Indication Red LED
(5) Battery Capacity 100% of the battery will provide 120 mins of monitoring; And 30 discharges at 360 joules.

Display
-LED Dimensions 7'diagonal {155mm*88mm}
-Type High resolution true-color graphic LED
-Resolution 480X234



ECG
ECG lead: I, II, III, AVR, AVL, AVF, V1~V6, GND
S-T segment analysis: -2.0~2.0mv
Arrhythmia analysis: Yes
Protegtion: With stand 4000vAc/50Hz voltage in isolation and work against eletrosurgical interence and defibrillation

Respiration
Measurement method: Thoracic impedance

NIBP
Working mode: Manual/Automatic/stat(5 minutes)
Method: Automatic oscillation
Cufftype: Standard Adult; Optional Pediatric/Neonatal

Temperature
Measurement range 20~45° C
Resolution 0.1° C

Pulse Oximetry(spO2)
Display: Spo2 value, pulse histongram, waveform, Pulse
Range: 0~99%for adult, pediatric and neonatal patients
Probe: Standard adult finger clip
Optional pediatric Y-type clip and neonatal wrap

Pulse range
Pulse range: 0-255bpm

Standard parameter & configuration
ECG/ RESP, /SPO2, /TEMP, /PR, /NIBP/DEFIBRILLATOR

Optional parameter
Recorder

Send your message to this supplier

*From:
*To:
avatar Mr. Aamon
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

Product Groups

Contact Supplier

Diamond Member Since 2009

Suppliers with verified business licenses

Manufacturer/Factory, Trading Company
Registered Capital
2000000 RMB
Plant Area
>2000 square meters