Customization: | Available |
---|---|
Customized: | Non-Customized |
Certification: | CE |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Introduction:
Hemodialysis, also known as artificial kidney and dialysis, is a kind of blood purification technology. It uses the principle of semi-permeable membrane to purify the blood through diffusion, remove various harmful metabolic wastes and excess electrolytes from the body, and absorb to correct the balance of water, electrolyte and acid-base.
For patients with renal insufficiency, hemodialysis is an important means to maintain the patient's life. When toxins accumulate to a certain extent in dialysis patients, the toxins in the body will endanger life and affect the function of various organs. Long-term maintenance of dialysis can excrete toxins and water in the patient's body, and maintain the acid-base and electrolyte balance in the patient's body.
Specification:
Size & Weight Size: 380mm×400mm×1380mm (L*W*H)
Area: 500*520 mm
Weight: 88KG
Power Supply AC220V, 50Hz / 60Hz, 10A
Input power: 1500W
Back-up battery: 30 minutes (optional)
Water input pressure: 0.15 MPa ~0.6 MPa
21.75 P.S.I. ~87 P.S.I.
Water input temperature: 10ºC~30ºC
Working environment: temperature 10ºC ~30ºC at relative humidity of no more than 70%.
Dialysate:
Dialysate temperature: preset range 34.0ºC~39.0ºC
Dialysate flux: 300~800 ml/min
Dialysate concentration: 12.1 mS/cm ~16.0 ms/cm, ±0.1 ms/cm
Dialysate mixing ratio: can set variety ratio.
UF rate Flow range: 0 ml/h ~4000 ml/h
Resolution ratio: 1ml
Precision: ±30 ml/h
Extracorporeal Part:
Venous pressure: -180 mmHg ~+600 mmHg, ±10 mmHg
Arterial pressure : -380 mmHg ~+400 mmHg, ±10 mmHg
TMP pressure : -180 mmHg ~+600 mmHg, ±20 mmHg
Blood pump flow range: 20 ml/min ~400 ml/min(diameter:6 mm)
Spare pump flow range: 30 ml/min ~600 ml/min(diameter:8 mm)
Resolution ratio: 1 ml
Precision: error range ±10ml or 10% of reading
Heparin Pump
Syringe size | 20, 30, 50 ml |
Flow range | 0 ml/h ~10 ml/h |
Resolution ratio | 0.1ml |
Precision | ±5% |
Sanitize
1.Hot decalcification :
Time: about 20 minutes
Temperature: 30~60ºC, 500ml/min.
2.Chemical disinfection :
Time: about 45 minutes
Temperature: 30~40ºC, 500ml/min.
3. Heat disinfection :
Time: about 60 minutes
Temperature: >85ºC, 300ml/min.
Storage Environment Storage temperature should be between 5ºC~40ºC, at relative humidity of no more than 80%.
Monitoring System
Dialysate temperature: preset range 34.0ºC~39.0ºC, ±0.5ºC
Blood leak detection: Photochromic
Alarm when erythrocyte specific volume is 0.32±0.02 or blood leak volume is equal or more than 1ml per liter of dialysate
Bubble detection: ultrasonic
Alarm when a single air bubble volume is more than 200µl at 200ml/min blood flow
Conductivity: acoustic-optic, ±0.5%
Some Accessories:
ONE STOP SHOPPING FOR HEMODIALYSIS:
1.Who we are?
We are based in Jiangsu, China, near Shanghai,start from 2008.We are the earliest manufacturer of export funeral products and medical equipment in China,sell to South America(20.00%),Southeast Asia(20.00%),North America(10.00%),Africa(10.00%),Eastern Asia(10.00%),Western Europe(10.00%),Southern Europe(10.00%),Domestic Market(10.00%).