Product Description
Fully Automatic Electronic Full body CPR Manikin
Model:THR-CPR01
AHA(American Heart Association) 2015 guideline for CPR and ECC
1. Nature standard of respiratory tract
2. Chest Compressions:
(1)Dynamic Bar code indicator can shows the depth of compression: standard compression depth(5-6 cm zone)is green light.
Below standard compression depth (less than 5 cm) is yellow light. Above standard compression depth(more than 6cm) is red light.
(2) Digital counter monitor:record the times of wrong and right press( times of strength is too hard, times of strength is too gentle,and wrong press positions)
(3)Language Indicator: Chinese /English Language, can indicates the reasons for the error,so that the student can corrects his/her operation in right way.
3.The Respiration Process(Mouth-to-Mouth)
(1) Inhalation from 500/600 ml to 1000 ml Dynamic light will shows both the quantity of inhalation volume,standard inhalation volume(500/600ml-1000ml) green light.Above or below inhalation volume,red or yellow light respectively
(2) Digital counter monitor shows the times of correct and wrong operations
(3)Voice prompt: Chinese /English Language, promptly indicates the reasons for the error,so that the student can corrects his/her operation in right way.
4.Ratio of compression and Mouth to Mouth operation: 30: 2(one or two person)
5.Operating cycle: One cycle includes five times of 30: 2 ratio of compression and Mouth to Mouth operation.
6.Operation frequency: 100 times per minute (the latest international standard)
7.Operation methods:Exercise operation; Examine operation;self-exercised operation
8.Operation time:Timing by the unit of second.
9.Sound prompting device: Volume control;Turning on or turning off sound prompting device
10. Detached Printer: Print operation result
11.Examination of pupil response: Mydriasis and myosis
12.Examination of carotid response: Touch carotid pulse with hand;Simulating spontaneous carotid pulse in compression process;Simulating spontaneous carotid pulse after examine operation
Materials
Face skin, cervical skin, chest skin and hair are made of thermoplastic elastomer and using technique of plastic injection mould with high temperature.The manikin has features of likelike touch, realistic operation feel.
CPR Monitor
Electronic monitoring: Electronic indicator lights are displayed to monitor airway opening and pressure locations.
Correct count and wrong count for artificial respiration and chest compressions.
Voice prompt: The whole process of training and assessment voice prompt, can turn on and off the voice, adjust the volume
Operation mode: CPR training, mode assessment and actual combat assessment can be carried out.
Print function: Print the operation process after the operation is finished.
Quick and convenient
Deluxe hand-push human body hard plastic box, to prevent product damage, to ensure that the product arrives in your hands.
1. Disinfect after use, such as face skin, mouth and nose, chest skin, breathing pipe, air intake valve, etc., can be scrubbed and disinfected with cleaning liquid.
2. When the lung sac device is broken and needs to be replaced, the chest skin can be opened, the cushion skin on the lung bag and the sensor blow pull rod are connected to take out the nail cap, remove the cushion skin, pull out the bellows at the connection of the lung bag and the tee pipe, replace the new lung bag according to the sample, assemble it as is, and restore the original.
3.The simulation of human and computer monitors, placed in a ventilated and dry place, must not be placed in a wet or sun-exposed place, to prevent affecting the service life.
4.Pay attention to the need for stable voltage when using.
1, Mouth to mouth artificial respiration, must be padded with disinfection gauze face towel (one-time blowing film), one person to prevent cross infection.
2.When operating hands should be clean, women please wipe lipstick and lip balm, to prevent dirty skin and breast skin, not allowed to use the original bead pen or other color pen to paint.
3.When pressing the operation, be sure to press the rhythm of the working frequency to avoid the disorder of the program, if there is a disorder of the program, immediately turn off the main power switch of the control display and reopen it to prevent the service life of the control display.
Packaging & Shipping
Company Profile