Customization: | Available |
---|---|
Classification: | Genes & Life Science Equipments |
Type: | PCR Machine |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Model
|
THR-gentier48E
|
Thermal block
|
|
Sample capacity(wells)
|
48
|
Reaction volume
|
5-100ul
|
Consumables
|
0.2ml 8-strip tubes,0.2ml PCR single tube(Optical flat cap. Clear tube)
|
Temperature range
|
0ºC-100ºC |
Heating/cooling system
|
Peltier
|
Max heating rate
|
8.0ºC/sec
|
Average heating rate
|
6.0ºC/sec
|
Max cooling rate
|
5.5ºC/sec
|
Average cooling rate
|
4.0ºC/sec
|
Temperature accuracy
|
±0.1ºC
|
Temperature uniformity
|
±0.1ºC
|
Gradient range
|
1ºC-40ºC
|
Gradient block
|
8row
|
Special temperature protocol
|
Gradient PCR, Long PCR, Touch Down PCR
|
Heat Lid
|
|
Temperature range
|
Room temperature-110ºC
|
Optical system
|
|
Excitation Source
|
4LEDs
|
Detector
|
Photodiode
|
Detection position
|
Excitation and scan from lateral
|
Detection method
|
4 channels scanning at the same time, no edge effect
|
Detection time
|
2 seconds for 48 wells for all channels
|
Range of excitation/emission wavelengths(nm)
|
1. 465/510(FAM,SYBR Green I,SYTO9,Eva Green,LC Green) 2. 527/563(HEX,VIC,TET,JOE) 3. 580/616(ROX,Texas Red) 4. 632/664(Cy5) |
Probe
|
Taqman Probe,Molecular beacons probe, scorpion probe
|
Multiplexing
|
Up to 4 targets
|
Fluorescence Linearity
|
r≥0.990
|
Fluorescence Dynamic Range
|
Adjustable
|
Performance
|
|
Sample Linearity
|
/r/≥0.999
|
Sample repeatability
|
Ct value CV≤0.5%
|
Sample dynamic Range
|
1-1010 copies
|
Software Functions
|
|
Data Analysis Modes
|
Qualitative analysis, Absolute quantification, Relative quantification, Genotyping analysis, Endpoint analysis, Melt curve analysis, High Resolution Melting |
Control Modes
|
1. 1. 7inch touch screen 2. PC direct control 3.WLAN control(one PC can control max 10 unis, and device can be controlled by any PC in the WLAN) |
Data Storage
|
Upload and download through USB disk, 1000 results can be stored in machine
|
Power failure protection
|
Automaticly start running experiments after power supply, no need wait PC software
|
Customize Report
|
Templetes reserved, report can customized
|
Administration Management
|
Administratior can set functions limits for users
|
Fault Management
|
Fault report and analysis,solution instruction
|
LIS connection
|
CSV,Excel,TXT format data output, open port for LIS connection
|
Others
|
|
PC operating system
|
Win7, Win 10
|
Communication Port
|
1 ethernet and 2 USB
|
Foot print(WxDxH)
|
260mmX400mmX260mm
|
Weight
|
11kg
|
Power usage
|
AC100 to 125V/200to 240V(50/60HZ)
|
Power consumption
|
600VA
|
Work environment
|
Temperature:10ºC~30ºC Humidity:20%~85%
|