![Vertical Laminar Air Flow Cabinet Laboratory Clean Bench Hood (THR-JHP-2)](//www.micstatic.com/athena/img/transparent.png)
Perfect products from Human engineering design. Sophisticated microcomputer control system, Optimal cleansing program, Originated from Europe and the United States manufacturing process, Qualified and first-class imported components to ensure perfectly clean environment appearance, best imported components, as well as advanced manufacturing technology of Europe and the United States, ensure your successful experiment.
Laminar flow hood
- Applicable in the field of protection of the needs of the biotechnology, pharmaceutical, life sciences and precision electronic products;
- Clean Bench combined with perfect airflow mechanical design for the operator to create a partial purification of the work environment so that experiments can be carried out smoothly;
- Comply with Australia AS1386.5 and the European Union EN12469 standard, clean grade of the international ISO14644.1 standard CLASS (U.S. Federal 209E, 100 level)
- IQ, OQ, PQ and other related certification services.
- CE certification. Three-year warranty period.
Micro-computer control technology
- Integrated LCD dot matrix LCD display, real-time display the status of lighting, sterile, air flow and other parameters.
- User-friendly design, with sterilization, lighting, interlock functions to protect the operator from UV light burns, and ensure safe operation.
- Wind speed multi-level adjustable, the air volume can be adjusted according to the user.
CLEANFLOWTM clean air technology
- Centrifugal wind wheel low-power motor, based on airflow mechanics principle, arc-shaped large-diameter inlet design to reduce turbulence generated to ensure low noise operation of the system.
- Reasonable duct design, optimized net press box, with micro-mesh design layer outflow wind deflector, convex, no dead ends, to ensure the uniformity and stability of the airflow.
- Standard early-efficient and efficient double-filter, primary filter to avoid airflow dust particles to enter and extend the life of high efficiency filter. High efficiency filter without clapboard HEPA, retention efficiency of 99.99%.
- According to the customer's requirements, CLEANFLOWTM series with the vertical flow and horizontal airflow
Ergonomically designed
![Vertical Laminar Air Flow Cabinet Laboratory Clean Bench Hood (THR-JHP-2)](//www.micstatic.com/athena/img/transparent.png)
- The front overall tilt design, low noise operation, increase operation comfort;
- Operating room standard with gas water interface, splash-proof power outlet to facilitate the experiments carried out smoothly;
- With weight up and down sliding front door, can be anchored;
- Built-in lighting system to provide the best illumination angle and brightness, reduce visual fatigue;
- On both sides of translucent double-glazed side windows, to enhance the light permeability, and non-convex design of the work area, no death and no spoiler design.
- The platform using an anti-corrosion resistance of SUS304 stainless steel plate forming the front of the arc-shaped design, and increase operator comfort.
![Vertical Laminar Air Flow Cabinet Laboratory Clean Bench Hood (THR-JHP-2)](//www.micstatic.com/athena/img/transparent.png)
Modern manufacturing processes
- Sheet metal parts use laser cutting and CNC bending technology. Cold-rolled sheets use three line of acidification anti-rust technology. Incubator surface use workmanship of spraying plastics.
Easy to clean
- 1. The early effect of the filter core and the air inlet stencil a shape, facilitate regular on the early effect of filter element folding loading and cleaning.
- 2. The polished design of the work surface as a whole, without pits, no dead ends on both sides, and a minimum of stitching design, easy to clean and disinfect.
Convenient maintenance
- Removable combination tripod, easy to transport and move, Stand height adjustable;
- Eversion design of the front control panel to facilitate the electrical components, maintenance and replacement;
- In order to make the device able to achieve long-term cleanliness requirements, it is recommended to the early effect of the equipment and high efficiency filter in use for some time to clean or replace.
![Vertical Laminar Air Flow Cabinet Laboratory Clean Bench Hood (THR-JHP-2)](//www.micstatic.com/athena/img/transparent.png)
Product type |
THR-JHP horizontal airflow |
THR-JHZ vertical airflow |
one person THR-JHP-1 |
two person THR-JHP-2 |
one person THR-JHZ-1 |
two person THR-JHZ-2 |
Cleanliness rating |
The international ISO 14644.1 standard, CLASS 5 (U.S. Federal 209E, 100 level) |
wind speed |
0.3~0.6m/s(Adjustable) |
Noise (dB) |
≤62 |
Vibration half peak |
≤3μm(X,Y,Z direction) |
High efficiency filter |
Efficiency 99.99% |
Illumination(LX) |
≥300 |
Work environment |
Ambient temperature 10~30ºC, Relative humidity below 70%, No obvious vibration and dust around |
Overall size(mm) (H×W×D) |
1585×990×735 |
1585×1460×735 |
1585×990×735 |
1585×1460×735 |
Inner size(mm) (H×W×D) |
500×830×550 |
500×1300×550 |
500×830×680 |
500×1300×680 |
Voltage(V)/ |
AC220V/50Hz |
Power(W) |
200 |
400 |
200 |
400 |
Net weight (KG) |
120 |
210 |
110 |
210 |
Shipping weight(KG) |
130 |
235 |
130 |
235 |
Packing size(mm) (H×W×D) |
1030×1180×855 |
1030×1650×855 |
1030×1180×855 |
1030×1650×855 |
Optional accessories
1, timed sterilization system;
2, the filter failure alarm procedures;
3, programmable UV sterilization control procedures;
4, can be equipped with the ULPA ultra-high efficiency filter (rejection rate of up to 99.999%)