THR-PM-210L-12 12.1 inch Color patient monitor
Central station software
Specification of Patient Monitor
Main Features:
1. Ergonomic design, portable, convenient for use
2. 8.4\ 10.4 \ 12.1\ 15 " TFT display, configurable up to 8 waveforms, enables maximum data visibility for the most critical parameters.
3. Unique digital SpO2 technology can work accurate during motion and low perfusion
4. Anti AC & high-frequency electrosurgical & defibrillator's interference
5. Rich screen layout, standard, large font, trend graph, OxyCRG, ECG full lead and others
6. Strong data storage: 720 hours trends, 10000 group NIBP, 1024 alarms events
7. ST analysis, arrhythmia analysis, pacemaker analysis, drug analysis and calculation
8. Audible & visual alarm available, adjustable
9. Patient information management function
10. Powerful software function to support use in NICU, ICU, OR, CCU or normal patient room
11. Flexible data storage & transfer/software upgrading based on USB
12. Wired/wireless networking with central monitoring system, up to 64 beds in one group
13. Built-in 3 trace thermal recorder for printing real-time and historical data
14. Multi-language I. E. English, Spanish, French, Italian, Turkish, German, Russian etc.
15. Super long life rechargeable dual lead-acid battery (optional) upto 4 hours of working time
16. Suitable for adult, pediatrics and neonate patients
Screen Size: 8.4" / 10.4" / 12.1" / 15"
Standard configuration:
ECG, NIBP, SpO2, TEMP, RESP, PR
ECG
1. Lead mode: I II III, AVR. VL. AVF. V
2. GAIN: *0.25. *0.5. *1. *2(mm/mV)
3. Hear rate: 15-300 bpm(adult); 15-350bpm(pediatric), Resolution: 1bpm, Accuracy: +-1%
4. Bandwidth: Diagnostic: 0.05-130Hz, Monitor: 0.5-40Hz, Surgery: 1-20Hz
5. Sweep speed: 12.5MMS, 25mm/s, 50mm/s
6. Pacemaker rejection: Yes
7. ST measurement Range: -2.0+-2.0mv
Accuracy: +-0.02mv or +-10% which is greater
SpO2
1. Measure range: 0-100%
2. Resolution: 1%
3. Accuracy: +-2%, Resolution: 1bpm, Accuracy: +-3bpm
NIBP
1. Work mode: Manual, automatic, continuous
2. Unit: MmHg, Kpa
3. Measure range:
Adult: SYS: 40-280mmhg, DIA: 10-220mmhg, MEAN: 20-240mmhg
Pediatric: SYS: 40-220mmhg, DIA: 10-160mmhg, MEAN: 20-170mmhg
Neonatal: SYS: 40-135mmhg, DIA: 10-100mmhg, MEAN: 20-100mmhg
4. Resolution: 1mmhg
5. Accuracy: Max mean error: +-5mmhg; Max standard deviation: 8mmhg
6. Overpressure protection: 0-300mmhg
7. Degree of protection: BF. CF
RESP
1. Measure range: Adult: 0-120rpm, pediatric. Neonatal 0-150rpm
2. Resolution: 1 rpm
3. Accuracy: +-2%
TEMP
1. Channels: 2
2. Measure range: 0-50° C
3. Resolution: 0.1° C
4. Accuracy: +-0.1° C(25-45c° )
Optional Parameters:
IPM
1. Channels: 2
2. Measure range: -50-360mmhg
3. Accuracy: +-2%or +-1mmhg which is greater
CO2
1. Measure range: 0%-13%
2. Resolution: 1mmhg
3. Accuracy: +-12mmhg@<5.0%CO2 (at ATPS)
4. Resp: 3-15rpm
IOC
1. EEG sensitivity: +-475UV
2. CMRR: >100dB
3. Input impedance: >50Mohm
4. IoC: 0-100
5. ESR: 0-100%
6. EMG: 0-100
Recorder
1. Width: 48mm
2. Speed: 25-50mm
3. Channels: 2
Package:
THR-PM-210L-10
Size: 296*216*440mm G. W.: 7.1kgs,
THR-PM-210L-12
Size: 296*216*440mm G. W.: 7.5kgs,