Customization: | Available |
---|---|
Classification: | Physiological Functions of Diagnosis and Monitoring Equipment |
Type: | Pulse Oximeter |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
1 | To switch on or off the Oximeter |
2 | It lights in green when the Oximeter is charged by AC adapter or connected to PC |
3 | It lights in red when power-on. |
4 | It moves cursor right in the monitoring display and alarm limit setup display,except the items under "clear data" and"data out", as well as moves the time index when reviewing trend waveformsas. |
5 | To change display screen |
6 | Down arrow/Clear data/Start data out, It begins to clear the data save, and to start data out, moves the time index in trend data review or print the data(optional). |
7 | It switches on or off the alarm sound and changes the items in the monitoring display and alarm limit setup display, or reviewing trend waveforms. |
8 | It moves cursor right in the monitoring display and alarm limit setup display except the items under "clear data" and"data out, as well as moves the time index when reviewing trend waveforms. |
9 | It changes the items in the monitoring display and alarm limit setup display, or reviewing trend waveforms. |
10 | When alarm is occur and the alarm function is on, the light will be red and flicker per second. |
11 | To connect SpO2 sensor |
12 | To connect TEMP probe |
13 | LCD and LED display, to display the real time data on LED display and to display the monitoring interface, alarm limit setup interface, trend waveform data onLCD |
WHAT ARE OUR PRODUCT FEATURES?
PLETH: The oximeter can display PLETH waveform
Audio and visual alarm: The speaker sounds the alarm, the parameters measurement flashes on the screen, sensor off alarm and LED flashes on the Oximeter.
Prompting: Icons of battery capacity, pulse sound switch and alarm sound switch.
Power saving: The Oximeter has auto power off function.
Data storage: Storage/Review trend data up to 3888 groups, data save time being set freely, The saved data will never be lost even if the oximeter is powered off.
Specifications
monitoring parameters:
PR,Sp02 and TEMP
SpO2
|
Patient: Adult, child
Range: 0~100%
Resolution: 1 %
Accuracy: 2 %(90~99%), 3 %(70~89%),unspecified<70%)
|
Pulse Rate
|
Range: 30~250bpm
Resolution: 1bpm
Accuracy: ±1bpm
|
Temperature
|
Channel: 1
Input: Body surface thermal-sensitive resistor temperature sensor
Measurement Unit: ºC/F selectable
Range: 0~50ºC
Resolution: 0.1ºC
Accuracy: ±0.2ºC
|
Signal sockets:
SpO2 socket and TEMP socket, adapter socket
Display screen
Type: 240 x 320 dot matrix color TFT LCD screen and LED screen
LCD Display area: 44mm x 59mm
LED Display area: 167mm x 79mm
Size; 280mm X 190mm x 100mm
Net Weight: 1000g (not include probes and adapter)
Electrical specifications
AC power adapter
Input: AC100V~ 240V, 50/60Hz, 0.7A
Ouput: DC5V,2A
Internal battery
Type: 200mAb/3.V Li rechargeable battery
Run Time: 10-15 hours of stand-by time with a full battery
Recharge time: 8 hours
Charge(discharge)≥1000times.
Environment
Temperature
Operation:0ºC~ 50ºC
Transportation and storage: -20°C~ 60ºC
Humidity
Operation: 10% ~ 95 %(non-condensing)
Transportation and storage: 10%~ 95 % (non-condensing)
Altitude
Operation: 86kPa ~ 106 kPa
Transportation and storage: 50kPa ~ 106 kPa