Usage: | Light, Industry |
---|---|
Output Type: | Dual |
Driving Method: | LED Constant Current |
Certification: | TUV, CE, RoHS, ISO9001 |
Power Supply Mode: | Constant Current Source |
Brand: | Thr |
Customization: |
---|
Suppliers with verified business licenses
OUTPUT
|
Output Voltage
|
12Vdc
|
Output Voltage Range
|
12Vdc±0.5Vdc
|
|
Output Current
|
Max.6.25A
|
|
Output Power
|
Max.75W
|
|
0utput Power Range
|
0~75W
|
|
Strobe Level
|
High frequency exemption level.
|
|
Dimming Range
|
0~100%, dimming depth: Max. 0.1%
|
|
Overload Power Limitation
|
≥102%
|
|
Ripple & Noise
|
≤200mV
|
|
PWM Frequency
|
3600Hz
|
|
INPUT
|
Dimming Interface
|
DALI, Push DIM
|
Input Voltage
|
220-240Vac
|
|
Frequency
|
50/60Hz
|
|
Input Current
|
Max.0.4A/230Vac
|
|
Power Factor
|
PF>0.97/230Vac, at full load
|
|
THD
|
≤14% at 230Vac, at full load
|
|
Efficiency
|
91%
|
|
Inrush Current
|
Cold start 30A at 230Vac
|
|
Control surge capability
|
L-N:2KV
|
|
Leakage Current
|
Max.0.5mA
|
|
ENVIRONMENT
|
Working Temperature
|
ta: -20°C ~ 50°C tc: 80°C
|
Working Humidity
|
20 ~ 95%RH, non-condensing
|
|
Storage Temp., Humidity
|
-40°C ~ 80°C, 10~ 95%RH
|
|
Temp. Coefficient
|
+0.03%/°C [0-50°C]
|
|
Vibration
|
10~500Hz, 2G 12min./1cycle, period for 72min. each along X, Y, Z axes
|
|
PROTECTION
|
Over-heat Protection
|
Intelligently adjusting or turning off the output current if the PCB temp
|
Over Voltage Protection
|
Shut down the output when non-load voltage≥13V, re-power on to recover after fault condition is removed
|
|
Over Load Protection
|
Shut down the output when current load≥102%, auto recovers.
|
|
Short Circuit Protection
|
Shut down automatically if short circuit
|
|
PACKAGE
|
Dimension
|
293x43x30mm
|
Packing
|
29 6x44x33mm
|
|
Weight
|
300g±10g
|
Suppliers with verified business licenses