Classification: | Imaging Diagnostic Equipment |
---|---|
Type: | Ultrasound Scanner |
Certification: | CE |
Group: | Female |
Standard: | ECG Resp Temp NIBP SpO2 Pr |
Monitor: | 8.4" 10.4" 12.1" 15" TFT Display |
Customization: |
---|
Suppliers with verified business licenses
Description of ecg machine | |
· Ergonomic design,portable,convenient for use | |
· 8.4" 10.4" 12.1" 15" TFT display,configurable up to 8 waveforms,enables maxmum data visibility for the most critical parameters | |
· Unique digital SPO2 technology can work accurate during motion and low perfusion | |
· Anti AC & high-frequency electrosurgical & defibrillator's interference | |
· Rich screen layout,standard,large font,trend graph,OxyCRG,ECG, full lead and others | |
· Strong data storage:720 hours trends,10000 group NIBP,1024 alarms events | |
· ST analysis,arrhythmia analysis,pacemaker analysis,drug analysis and caculation | |
· Audible & visual alarm available,adjustable | |
· Patient information management function | |
· Powerful software function to support use in NICU,ICU,OR,CCU or normal patient room | |
· Flexible data storage & transfer/software upgrading based on USB | |
· Wired/wireless networking with central monitoring system,up to 64 beds in one group | |
· Built-in 3 trace thermal recorder for printing real-time and historal data | |
· Muilti-language i.e. English,Spanish,French,Italian,Turkish,German,Russian etc. | |
· Super long life rechargeable dual lead-acid battery | |
· Suitable for adult,pediatrics and neonate patients | |
Technical parameter | |
Standard: | |
ECG RESP TEMP NIBP SPO2 PR | |
Optional: | |
CO2,Recorder,IBP |
ECG
1.Lead mode:I II III,AVR.VL.AVF.V .
2.GAIN:*0.25.*0.5.*1.*2(mm/mV)
3.Hear rate: 15-300 bpm(adult); 15-350bpm(pediatric),Resolution:1bpm, Accuracy:+-1%
4.Bandwidth: Diagnostic:0.05-130Hz,Monitor:0.5-40Hz,Surgery:1-20Hz
5.Sweep speed:12.5mms,25mm/s,50mm/s
6.Pacemaker rejection:Yes
7.ST measurement Range:-2.0+-2.0mv
Accuracy:+-0.02mv or +-10% which is greater
SPO2
1.Measure range:0-100%
2.Resolution:1%
3.Accuracy:+-2%, Resolution:1bpm, Accuracy:+-3bpm
NIBP
1 Work mode: manual,automatic,continuous
2 Unit: mmHg,Kpa
3 Measure range: adult: SYS:40-280mmhg
DIA:10-220mmhg
MEAN:20-240mmhg
Pediatric:SYS:40-220mmhg
• DIA:10-160mmhg
• MEAN:20-170mmhg
• Neonatal:SYS:40-135mmhg
• DIA:10-100mmhg
• MEAN:20-100mmhg
4 Resolution:1mmhg
5 Accuracy: max mean error:+-5mmhg; max standard deviation:8mmhg
6 Overpressure protection:0-300mmhg
7 Degree of protection:BF.CF
RESP
1 Measure range: Adult:0-120rpm
• pediatric.neonatal 0-150rpm
2 Resolution:1 rpm
3 Accuracy:+-2%
TEMP
1 Channels:2
2 Measure range:0-50°c
3 Resolution:0.1°c
4 Accuracy:+-0.1°c(25-45c°)