Customization: | Available |
---|---|
Type: | Infusion Pump |
Certification: | CE, ISO13485 |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Safe and reliable
1.1 Using double CPU design, reliable data transmission, safer infusion.
1.2 Upper and lower duble occlusion pressure sensors design, upper-occlusion sensor can avoid underflow effectively, 10 adjustable level settings for occlusion by lower- occlusion.
1.3 Real-time self-testing,real-time self-testing when startup and during infusing process, ensure the safety of each component and each function, safer infusion.
.4 Automatic switching between AC and DC power supply , backup time more than 10hours under battery supply to ensure no interruption when no AC power supply or in moving condition.
1.5 Alarm prompt with sound, light and message, 10 adjustable level of alarm volume.
1.6 Dynamic pressure value display, and real-time detect occlusion pressure status.
1.7 Various alarm, avoid the suddenly accidents during infusion process.
1.8 Motor anti-reverse function, avoid preventing upstream absolutely.
Specification
|
|
Infusion Mode
|
Volume Mode, Time mode, Drug Mode, Bolus Mode, Drip Mode
|
Rate Unit
|
Ml/h, volume/time, d/min
|
IV Sets
|
Standard single use IV sets(20 and 60d/ml, with diameter 3.4~4.5mm)
|
Flow Rate
|
1.0ml/h~1200ml/h; 1.0d/min~400/min
|
Increment
|
1.0-99.9ml/h with 0.1ml/h; 100-1200ml/h with 1ml/h
|
Flow Rate Deviation
|
<±5%(after calibration)
|
VTBI
|
0.1~9999ml
|
Infused Volume
|
0~999ml
|
Time Setting
|
1 min to 99h59min
|
Purge Rate
|
600ml/h, displaying purge volume
|
KVO
|
0.1ml/h~5.0ml/h, adjustable
|
Keypad
|
Numeric Keypad, user friendly
|
BOLUS Mode
|
Available for Bolus mode, flow rate adjustable
|
Night Mode
|
Night mode, No operation for 5mins, LCD brightness lower automatically
|
Occlusion Pressure Detection
|
Upstream and downstream pressure detection, detection range: 40-130Kpa, 0~9 levels adjustable, dynamic pressure value display
|
Air bubble Detection
|
Ultrasonic detection, ≥50μL , Single bubble volume: 50~300μL , 0~9 levels adjustable
|
Alarm &Volume
|
0~9 levels adjustable
|
Anti-reverse Function
|
Anti-reverse function on motor to prevent upstream
|
IV Set Management
|
Open System, Can accept all kinds of IV Set after calibration
|
Self-Testing
|
Self-Testing when start up and during infusing
|
Audio and Visual Alarms
|
Air bubble, upstream occlusion, downstream occlusion, door open, infusion finish, standby time expired, battery low, battery low, battery empty, battery disengaged, AC Power disengaged, Motor error, pump error, pressure sensor error, parameter error, system abnormal. |
Screen
|
3.2" Brightness LCD
|
Power Supply
|
AC:100V~240V, 50Hz/60Hz,≤25VA
|
Battery
|
Rechargeable Lithium battery: DC11.1V, 3000mAh, life:≥10 hours@25ml/h, displaying remaining battery
|
Operation Condition
|
Temperature: 5ºC~40ºC, Relative humidity:20%~80%, Atmospheric pressure:70~106Kpa
|
Transportation and Storage
|
Temperature: -20ºC~55ºC, Relative humidity:10%~95%, Atmospheric pressure:50~106Kpa
|
Classification
|
Type CF, Class I, IPX3, ISO13485, CE, IEC60601
|
Dimension
|
145mm*150mm*200mm
|
Weight
|
1.7KG
|