FEATURES
|
|
Core
|
--Newly advanced A9 main board with Linux OS,calculating speed is 4 times faster than traditional products
--Support storage of 2160 hours trend table and graph review, 2 hours waveform review, 2000 groups NIBP review and 2000 alarm events review
|
Body
|
--12.1 inch high-brightness TFT LED --Support display 9~12 waveforms --Support 7 channel ECG waveform display --Optional touch screen |
Printer
|
--Built-in high-speed 50mm thermal printer(Brand: SEIKO, Japan)
|
Central System
|
--Support wired/wireless connection to the central monitoring station.
|
Alarm
|
--Three-level acousto-optic alarm --Sensor-off alarm --Paper out alarm --Support alarm review --Support alarm pause |
OS
|
--Support operation with mouse and computer keyboard (option) --Multi-display mode to meet different clinical requirement, including standard, big font, OxyCRG, trend graph, NIBP review and full leads ECG interface. --NIBP self-test mode: including overpressure test, static pressure test and air leakage test. --Generate ID automatically when register a new patient --Support medical history search by patient ID, name and mobile number --18 types of Arrhythmia analysis and real-time S-T segment analysis and pacemaker detection --Drug calculation and titration table --Support multi-language display --Support online software upgrading by net/USB |
Performance Specifications
|
|
Dimension and Weight
|
- Dimension: 375mm*330mm*180mm - Weight: 3.4kg (excluding accessories) |
Power Supply
|
- Voltage: AC100~240V, 50/60HZ, - Power≤60W |
Display
|
- 12.1" color TFT LED - Resolution: 800*600 pixels |
Battery
|
-Type: Rechargeable lithium battery: 12V/2200mAh
- Charge Cycle: ≥500 times
- Working time: 2 hours
|
Recorder (Option)
|
- Method: Thermal printer - Paper width: 50 mm (1.97 in) - Printing speed: 12.5/ 25/ 50 mm/s - Trace: Max. 3 tracks - Recording way: Real-time Recording, Review Printing, Periodic Recording, Alarm Recording |
Alarm
|
- Level: Low, medium and high - Indication: Auditory and visual - Alarm volume adjustable - Alarm pause time: 1min, 2min - Parameter alarm type: Latch/ Unlatch |
Input Device
|
- Touch screen (option) - Knob (Standard) - Keypad input (Standard) - Mouse/ Keyboard input (option) |
System Output & Extensible Interface |
- Ethernet Network: 1 standard RJ45 socket
|
Safety
|
- IEC60601-1 Approved,
CE marking according to MDD93/42/EEC
- With reference to RoHS Directive 2011/65/EU recasting |
Trend & Reviewing
|
- Trend: 2160 hours - ARR events: 128 groups of ARR events and associated waveform - NIBP measurement reviewing: 2000 groups - Waveform review: 2 hours Alarm event: 2000 groups of parameter alarms events and associated parameter |
ECG
|
- Lead mode: 3/5 Leads, I, II, III or I, II, III, AVR, AVL,AVF, V - Gain: 2.5mm/mV(×0.25), 5.0mm/mV(×0.5), 10mm/mV (×1), 20mm/mV (×2), 40 mm/ mV (×4), Auto - Sweep speed: 6.25mm/s, 12.5mm/s, 25mm/s, 50 mm/s - ECG signal range: ±12 mV (Gain × 0.25) Auto - ECG signal range: ±6 mV - Accuracy: ±1bpm/ ±1%, whichever is greater - Resolution: 1 bpm - Leakage Current < 10 μA - Baseline Recovery:< 5 s after defibrillation (MOR or Surgery mode) - Bandwidth: Surgery 1 ~ 20 Hz Monitor 0.5 ~ 40 Hz Diagnostic 0.05 ~ 130 Hz - Indication of Electrode Separation: Every electrode (exclusive of RL) |
Heart Rate
|
- Measure range: Adult: 0bpm; 15 ~ 300 bpm Neo/Ped: 0bpm; 15 ~ 350 bpm - Resolution: 1 bpm - Accuracy: ± 1% or ± 1bpm, whichever is greater |
ST Measurement
|
- Range: -2.0 ~ +2.0 mV - Accuracy: -0.8mV ~ +0.8mV: ±0.02mV or ±10%,whichever is greater - Other range: unspecified - Resolution: 0.01mV |
Respiration
|
- Method: Impedance between RA-LL, RA-LA - Gain: ×0.25, ×0.50, ×1, ×2 - Respiration Rate: Adult: 0 ~ 120 BrPM; Neonatal / Pediatric: 0 ~ 150 BrPM - Resolution: 1 BrPM - Accuracy: ±2 bpm or ±2%, whichever is greater - Apnea Alarm: 10 ~ 40 s |
SpO2 (Analog Technic)
|
- Measurement Range: 0 ~ 100 % - Resolution: 1 % - Accuracy: 70% ~ 100%: ±2 % 40% ~ 69%, ±3 %; <39%, unspecified; |
Pulse Rate
|
- Measuring and Alarm Range: 20~300bpm - Accuracy: ±3bpm - Resolution: 1bpm |
Nellcor-SpO2 (Option)
|
- Measurement Range: 0 ~ 100 % - Resolution: 1 % - Accuracy: 70% ~ 100%, ±2 % (adult) 70% ~ 100%, ±3 % (Neonate) 70% ~ 100%, ±2 % (Low Perfusion) 0% ~ 69%, unspecified |
Pulse Rate
|
- Measurement range: 20 ~ 300 bpm - Resolution: 1bpm - Accuracy:±3 bpm (20 ~ 250 bpm) Unspecified (251~300 bpm) |
Masimo-SpO2 (Option)
|
- Measurement Range: 0 ~ 100 % - Resolution: 1 % - Accuracy: 70% ~ 100%, ±2 % (adult/ pediatric, non-motion conditions) 70% ~ 100%, ±3 % (neonate, non-motion conditions) 70% ~ 100%, ±3 % (motion conditions) 0% ~ 69% unspecified |
Pulse Rate
|
- Measurement range: 25 ~ 240 bpm - Resolution: 1bpm - Accuracy: ±3 bpm (non-motion condition) |
Temperature
|
- Technique: Thermistor probe (2.25K/10K) - Channel: Dual-Channel, provide T1; T2; ΔT - Measuring and Alarm Range: 0.0 ºC~ 50 ºC (32ºF~ 122ºF) - Unit: Celsius (ºC), Fahrenheit ( ºF) - Resolution: 0.1ºCor 1ºF - Accuracy: ±0.1ºC(exclusive probe error) |
NIBP
|
- Method: Oscillometric - Measure mode: Manual, Auto, STAT - STAT mode cycle time: Keep 5 minutes, at 5 seconds interval - Measure Interval in AUTO Mode: 1,2,3,4,5,10,15,30,60,90,120,180,480 min - Measure and Alarm Range:
Adult: SYS: 40 ~ 280 mmHg
DIA: 10 ~ 220 mmHg MEAN: 20 ~ 240 mmHg Pediatric: SYS: 40 ~ 220 mmHg
DIA: 10 ~ 160 mmHg
MEAN: 20 ~ 170 mmHg Neonate: SYS: 40 ~ 135 mmHg DIA: 10 ~ 100 mmHg MEAN: 20 ~ 110 mmHg - Static pressure accuracy: ±3mmHg - Resolution: 1mmHg - Accuracy: Maximum Mean error ±5mmHg Maximum Standard deviation ≤8mmHg - Over pressure Protection: Dual protection via software & hardware |
EtCO2 (Mainstream) (Option)
|
- Measure method: Non-dispersive infrared (NDIR) - Measure Range: 0 ~19.7% (0 ~ 150 mmHg) 0 ~ 20 kPa - Resolution: 0.1 mmHg - CO2 Accuracy: 0 ~ 40 mmHg, ±2 mmHg 41 ~ 70 mmHg, ±5% of reading 71 ~ 100 mmHg, ±8% of reading 101~ 150 mmHg, ±10% of reading at 760 mmHg, ambient temperature of 25ºC) - Respiratory Rate: Range: 3 ~150 BrPM Accuracy: ±1 bpm |
IBP (Option)
|
- Max Channel: 2 - Measurement way: Thermal resistance way - Press Sensor: Sensitivity 5 uV/V/mmHg, ±2% Impedance 300 to 3000Ω - Resolution: 1 mmHg - Unit: mmKg, kPa |
IBP (Option)
|
-Transducer sites: Arterial Pressure (ART) Pulmonary Arterial (PA) Left Arterial (LAP) Right Arterial (RAP) Central Venous Pressure (CVP) Intracranial Pressure (ICP) P1/ P2 - Measuring and alarm range: ART 0 ~ +350mmHg PA -6 ~ +120 mmHg CVP/ RAP/ LAP/ ICP -10 ~ +40 mmHg P1/ P2 -10 ~ +300mmHg - Accuracy: Static: ±1mmHg or ±2%, whichever is greater (exclusive of transducer) ±4mmHg or ±4%, whichever is greater (inclusive of transducer) Dynamic: ±4mmHg or ±4%, whichever is greater |