Customization: | Available |
---|---|
Type: | Gas Sterilization Equipments |
Certification: | CE, ISO13485 |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Heating method | Electric heating |
Power | 3.0kW AC.220V, frequency 50Hz |
Dimensions (Length × Width × Height) | 976 × 790 × 1715mm |
Liner size(Length × Width × Height) | 700 × 450 × 400mm |
Effective Volume | 126L |
Weight | 210KG |
Temperature display | LCD touch screen |
Material of Sterilization Room | Aluminium 5052 |
Outer box material | ABS board (5mm thick) spray paint |
Temperature during sterilization | 50 ºC |
Working pressure | -60kpa |
Highest anti-stress value | -80kpa |
Humidity during sterilization | 45% -75% |
Selected gas | Pure ethylene oxide gas |
Sterilization time | 0-99 hours adjustable |
Vacuum speed | pumped to -60kpa in 5 minutes |
Air Replacement | Automatic ventilation, 5 cycles of ventilation, every 15 minutes |
Full-automatic control system | One-click start to finish, the whole process is completed automatically |
Display status | Display operating status, temperature, humidity, pressure, sterilization time, residual gas treatment time, times, steam generator temperature. |
Display status | Display operating status, temperature, humidity, pressure, sterilization time, residual gas treatment time, times, steam generator temperature. |
Printer | A micro-printer is used to print out all data during the entire sterilization process, which can be permanently saved. |
Humidity Sensor | The built-in humidity sensor automatically detects the humidity in the cavity. |
Pressure Sensor | The built-in pressure sensor automatically detects the pressure in the cavity. |
Temperature Sensor | The built-in temperature sensor automatically detects the temperature in the cavity, the accurate range is 50 ºC ± 3 ºC. |
Sealed door | 5052 high-quality aluminum door panel, thickness ≥ 2mm, key open, anti-pressure 200Kpa |
Humidification System | Humidification System |
Air intake device | The filtration rate of the filter to the particle diameter ≥0.3μm is not less than 99.5%. |
Leakage rate of sterilization chamber | The measurement of the leakage rate is carried out under the conditions of no load, the temperature of the sterilization chamber is unchanged, the test pressure is -50kPa, and the measurement time is 1h. The average leakage rate within the measurement time is ≤0.16kPa / min. |
Vacuum rate | Under no-load conditions, the time for the sterilizer to be vacuumed from normal pressure to -60kPa should be ≤10min. |
Automatic dosing | China's built-in piercing technology. |
Automatic memory recovery function | When the power is cut off unexpectedly, the sterilizer will automatically remember the state when it is stopped. |
Heating system | Adopt flame retardant and explosion-proof electric heating system, heating on six sides. |
Various protection functions | With over-voltage, leakage and over-temperature protection functions, it is more safe and reliable. |
Alarm system | here are high and low temperature alarm system, high and low pressure alarm system, leak rate detection alarm system, high and low humidity alarm system, sealed door detection alarm system, dosing detection alarm system |
Power-off memory function |
If the power is cut off during the sterilization process, the screen will prompt "Yes" and "No" to continue the previous operation after the power is turned on again. At this time, you can select "Yes" to continue the last run. You can also choose "No" to cancel the operation. |